For S21 Hyd.,S19 Hyd.,T19 Hyd.,T19 Pro Hyd.,S19 Pro Hyd.,S19 Pro+ Hyd.,S19 XP Hyd.,S19e XP Hyd.,S21 XP Hyd.
Note:
Please update your ANTMINER with the newest firmware accordingly after replacing the power supply. Download the firmware
*If you need purchase these materials, please contact us. For more operation guidance please refer to this article《APW11 PSU Replacement Instructions》
| Product Glance | |
| Out1 | |
| DC Voltage | 17V-21.6V |
| Rated Current(380V input) | 300A |
| Rated Power(380Vinput) | 6500W |
| Ripple & Noise | <1% |
| Line Regulation | <1% |
| Load Regulation | <1% |
| Setup Time | <5S |
| Short Circuit Protection | >10mS |
| Detailed Characteristics | |
| Out2 | |
| DC Voltage | 12.3V |
| Rated Current(220 V input) | 1A |
| Ripple & Noise | <1% |
| Voltage Accuracy | 12.2V—12.4V |
| Line Regulation | <1% |
| Load Regulation | <1% |
| Setup Time | <5S |
| Short Circuit Protection | >10mS |
| Input | |
| Voltage Range | 380-415V AC |
| Frequency Range | 50~60 Hz |
| Power Factor | >0.99(full load) |
| Leakage Current | <1.5mA(380V 50Hz) |
| Protection | |
| Low-voltage Input | < 304V AC |
| Output Short Circuit | Yes |
| Overheat Protection | Yes |
| Over-current Output | 300A-350A |
| Environment | |
| Operating Temperature | -20-45℃ |
| Operating Humidity | 20%-90%RH(non–condensing) |
| Altitude | < 2000m |
| Structure | |
| Dimensions | 320mm*179mm*63mm |
| Net Weight | 5kg |
| Cooling System | Water cooling |
| Inlet temperature | 20-35 ℃ |
| Water flow rate | 8L/min |
| Water pressure | <3.5 BAR |




Reviews